Back
source
Primary source
  • This is a primary source
Updated Apr 24, 2026

Labor rates — Q2 2026

By WEA Operations
Published Apr 1, 2026
Original source
pricinglaborrates

Labor rates — Q2 2026

All rates are ex GST. GST is applied at the quote total per gst-tax. Minimum charge is 2 hours for any site attendance.

Field labor

RoleStandard (Mon–Fri 07:00–17:00)SaturdaySunday / Public Holiday
A-grade electrician128.00192.00256.00
Industrial electrician (Level 2 ASP)148.00222.00296.00
4th-year apprentice78.00117.00156.00
2nd-year apprentice58.0087.00116.00
Labourer62.0093.00124.00

Rates are per-hour, per-person, AUD, ex GST.

Supervision and design

RoleRate (AUD/hr, ex GST)
Project supervisor165.00
Site manager195.00
Electrical designer / drafter185.00
Principal engineer245.00

Supervision is billed for planned site attendance; ad-hoc phone support during a project is absorbed into project overhead and not charged separately.

After-hours call-out

  • Minimum 4-hour charge at the Sunday / public-holiday rate.
  • Travel time is billed door-to-door at the on-call rate.
  • Available to existing contract clients only; one-off work is scheduled to standard hours.

Travel

  • Work within 25 km of Port Melbourne depot: no travel surcharge.
  • 25–80 km: $95 per trip (per vehicle), absorbed into the quote as a separate line item.
  • 80–250 km: travel time billed at the field labor rate, plus $0.90 per km running cost, plus accommodation at cost (capped at $180 per night per technician) for overnight jobs.
  • Beyond 250 km: quoted case-by-case; project supervisor sign-off required before quote release.

Productivity assumptions for quoting

Use these defaults when a specific task estimate is not available:

TaskCrewHours
Main switchboard (≤ 400 A) replacement1 A + 1 apprentice16
Main switchboard (> 400 A) replacement1 A + 1 supervisor + 1 apprentice28
Distribution board installation (24–48 pole)1 A + 1 apprentice6
Sub-main run, per 10 m (including containment)1 A + 1 apprentice1.5
Final circuit, general power, per point1 A + 1 apprentice0.7
Emergency lighting fixture, supply + install1 A0.5
Thermal imaging (preventative, up to 200 circuits)1 A4
Commissioning and certification (per switchboard)1 A or supervisor3

These are hours on-site; travel is additional per the travel rules.

Neighborhood